Gb 50034—2013

WebJul 3, 2016 · UDC 中华人民共和国国家标准 ~~ P GB 50034-2013 建筑照明设计标准Standard for lighting design of buildings 2013-11- 29 发布 2014 - 06 - 01 实施中华人民共 … WebApr 1, 2014 · 摘要: 《中华人民共和国行业标准(gb 50034-2013):建筑照明设计标准》修订的主要技术内容是修改了原标准规定的照明功率密度限值;补充了图书馆、博览、会展、 …

Research on Virtual Simulation Evaluation System for ... - Springer

http://kscecs.com/standard/searchStandardDetail.action?standardId=9227 WebGB 50033-2013 English Version - GB 50033-2013 Standard for daylighting design of buildings (English Version): GB 50033-2013, GB/T 50033-2013, GBT 50033-2013, GB50033-2013, GB 50033, GB50033, GB/T50033-2013, GB/T 50033, GB/T50033, GBT50033-2013, GBT 50033, GBT50033 top service construction https://csgcorp.net

GB 50034-2013: Translated English of Chinese Standard.

WebJan 7, 2015 · According to “Standard for Lighting Design of Buildings (GB 50034-2013)” of China, the standard luminance for service hall should be 200 lx, and the corresponding illumination power density is 9 W/m 2. Therefore, if the luminance of visitor centre reached 200 lx, the per unit power consumption would achieve 9 W/m 2. WebGB 50049-2011 English Version - GB 50049-2011 Code for design of small fossil fired power plant (English Version): GB 50049-2011, GB/T 50049-2011, GBT 50049-2011, GB50049-2011, GB 50049, GB50049, GB/T50049-2011, GB/T 50049, GB/T50049, GBT50049-2011, GBT 50049, GBT50049 WebApr 2, 2024 · GB 50034-2013 Architectural lighting design standards 3 Terms and definitions GB/T 33170.1-2016, GB/T 33170.5-2016, GB 50034-2013 and GB/T 36724-2024 and The following terms and definitions apply to this document. For ease of use, GB/T 33170.1-2016 is repeatedly listed below. top service credit reports

antpedia.com

Category:GB 50034-2013 English Version, GB 50034-2013 Standard for ligh…

Tags:Gb 50034—2013

Gb 50034—2013

Solar Lighting Technologies for Highway Green Rest Areas in …

WebP GB 50034-2013. Standard for Lighting Design of Buildings. ISSUED ON. NOVEMBER 29, 2013. IMPLEMENTED ON. JUNE 1, 2014. Jointly Issued by the Ministry of Housing and … WebMay 1, 2024 · 修订说明. 《建筑照明设计标准》GB 50034-2013,经住房和城乡建设部2013年11月29日以第243号公告批准、发布。. 本标准是在《建筑照明设计标准》GB 50034 …

Gb 50034—2013

Did you know?

Webantpedia.com WebJun 1, 2014 · 根据住房和城乡建设部《关于印发<2011年工程建设标准规范制订、修订计划>的通知》 (建标 [2011]17号)的要求,由中国建筑科学研究院会同有关单位对原国家标准 …

Web建筑照明设计标准(英文版) GB 50034-2013 现行 Standard for Lighting Design of Buildings 收藏 发布日期: 2013-11-29 实施日期: 2014-06-01 主编部门: Ministry of Housing and Urban-Rural Development of the People's Republic of China 主编单位: China Academy of Building Research WebJan 1, 2015 · According to the mandatory standards GB 50034-2013 “Standard for lighting design of buildings” [ 7 ], the lighting standard value of normal supermarkets should be 300 lx and of high range market should be 500 lx. Moreover, the lighting standard values of kitchens and living rooms should be 100 lx–150 lx and 100 lx–300 lx respectively.

WebJan 1, 2024 · According to the standard, the common grid is optimized. By increasing the shading angle of C0°-180° and reducing the shading angle of C90°-270°, it can reduce the glare and achieve the classroom... WebAug 5, 2024 · Set the daylighting reference plane 0.75 m from the ground, and the design illuminance is 300 LX according to the requirements of GB 50034–2013 standard for lighting design of buildings . When the natural daylighting illuminance is insufficient, the lighting system is turned on for the supplement.

WebJun 24, 2024 · GB 50034-2013. Standard for lighting design of buildings. National standard of the People's Republic of China Jan 2014 CABP 2014. GB 50034-2013. Standard for lighting design of buildings....

WebA minimum frequency of 90 Hz at all 10% light output intervals from 10% to 100% light output. [ 69] LED products with a “low risk” level of flicker (light modulation) of less than 5%, especially below 90 Hz operation as defined by IEEE standard 1789-2015 LED. [ 69] top service creditWebJan 7, 2024 · GB 50034–2013: Standard for Lighting Design of Buildings. Ministry of Housing and Urban-Rural Development of China. Beijing: China Architecture & Building Press. (in Chinese) Google Scholar MOHURD (2015). GB 50189–2015: Design Standard for Energy Efficiency of Public Buildings. Ministry of Housing and Urban-Rural Development … top service credit checkWebMar 20, 2024 · The light environment was analyzed in terms of the illuminance, daylight factor, uniformity ratio of illuminance and uniformity of daylighting. The reading room standard in GB 50034-2013 and GB 50033-2013 were used to evaluate the light environment of the self-study area in the library. top service debt recoveryWebJun 14, 2024 · As an important index in the lighting design for subway passenger compartments, discomfort glare is regarded as a significant lighting quality index in Chinese lighting standards (e.g. Standard for Lighting Design of Buildings (GB 50034-2013)). LES1.0 also uses the UGR (Unified Glare Rating) system proposed by Commission International … top service dog organizationsWebThe circular light-emitting panel, with a diameter of 116 mm and coupled with professional LED lamp beads, provides more even light distribution over an even larger area. Vivid, true-to-life CRI Let your creativity shine through Bring the world around you to life with true-colour enhancing, natural illumination. top service debt collectorsWebApr 8, 2024 · Auto delivery. Architectural lighting design standards. GB 50033-2013. Valid. GB 50033-2013. SIMILAR Google-Books for your assessment (Full-PDF of GB 50033-2013_English will be auto-delivered in 0~3 mins): GB 50033-2013 GB/T 38539-2024 GB/T 50087-2013 GB 50034-2013 GB 50264-2013. top service dinner cruise on the river tiberWebGB 55015-2024 English Version - GB 55015-2024 General code for energy efficiency and renewable energy application in buildings (English Version): GB 55015-2024, GB/T … top service dritte